Welcome! Use the login menu to access:
Customer Portal
SolarWinds customers can download purchased software, renew maintenance, & more in our updated Customer Portal!
Community
After logging in, community members can rate & review SolarWinds software & participate in forums on thwack.com.
Partner Portal
SolarWinds channel partners will find all the resources they need in the Partner Portal, including exclusive partner tools.
| More

SolarWinds Knowledge Base

View Articles by Category

Category Icon Additional Web Server (NTA) (21)
Category Icon CBQoS (NTA) (13)
Category Icon Configuration (NTA) (23)
Category Icon Configuration Wizard (NTA) (15)
Category Icon Database (NTA) (55)
Category Icon Device Configuration (NTA) (26)
Category Icon Devices (NTA) (26)
Category Icon Flows (NTA) (31)
Category Icon Installing, Migrating, Upgrading, Licensing (NTA) (68)
Category Icon Performance Enhancement (NTA) (11)
Category Icon SCOM (NTA) (2)
Category Icon Security (NTA) (20)
Category Icon Templates (NTA) (1)
Category Icon Web Console (NTA) (84)
Add an article to this category

Category » Orion NetFlow Traffic Analyzer (NTA)rss button

(Page 1 of 10)      Prev | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | Next

There were 192 articles found in this category:

  1. questionWhat browsers are supported for use with the Orion Web Console?
    The following browsers are supported for the Orion Web Console. Orion Core 2011.2.X Orion Core 2011.1.X Orion Core 2010.2.X Orion Core 2010.1.X Internet Explorer 9 ✔ ✖ ✖ ✖ Internet Explorer 8 ✔ ✔ ✖ ✖ Internet Explorer 7 ✔ ...
  2. questionHow to upgrade SolarWinds Orion products
    SolarWinds Orion modules and standalone products are compatible with the specific versions of SolarWinds Orion Network Performance Monitor (NPM) shown in the following tables. Standalone products do not require any other SolarWinds products to be installed. To upgrade from earlier versions of O ...
  3. questionSNMP on Cisco Nexus 5000: libcmd() Process Has Memory Leak
    snmp memory leak associated with libcmd() Symptom: The process libcmd has a memory leak and is increasing in memory. Timeouts can be seen when the Nexus 5000 is snmp polled from a network management server. Conditions: Nexus 5000 switch enabled for snmp and the BRIDGE-MIB is being snmp polle ...
  4. questionEnabling audible alerts (Play a Sound action) on Windows Server 2008
    Due to restrictions on Windows service applications, the Play a Sound action is not available to SolarWinds installations on either Windows 7 or Windows Server 2008 and higher. The following procedure provides a workaround to give you audible alerts. To configure a play sound action for an adva ...
  5. questionDuplicate Flows
    Explanation: There are three known scenarios in which duplicate flows occur. Scenario # 1 When customers have both “ip flow ingress” and “ip flow egress” applied to the interfaces Resolution: Remove the “ip flow egress” command from the interfaces and only hav ...
  6. questionTraffic data presented as pie chart does not add up to 100%
    Issue: Traffic data pie charts are presented with a table that provides node related details. If there are sources of traffic in the table that are not atrributable to monitored nodes, those sources are combined into an 'Other' category and the percentage number is cumulative for all such source ...
  7. questionConsiderations for changing locales (Upgrading to NPM 10.3 and Orion Platform 2012.1)
    Please consider the following when upgrading your current SolarWinds Orion installation to a localized version based on SolarWinds Platform version 2012.1. and higher: Issue: Direct upgrades from SolarWinds Orion NPM version 10.2.X and older (English) to SolarWinds Orion NPM version 10.3 (Jap ...
  8. questionSolarWinds and ASP.NET applications (WSUS, OWA, SharePoint)
    Generally, SolarWinds recommends against running WSUS, OWA (Outlook Web Access/App), SharePoint or other ASP.NET applications on your Orion server, as other ASP.NET applications may require additional security affecting the anonymous user. However, if the correct compression scheme is enabled, W ...
  9. questionCPU Load and Memory is reporting incorrectly for H3C devices
    Issue: CPU Load and Memory data are displaying incorrectly in the web console for H3C devices. Description: SolarWinds Orion sums all non-zero polled values for all CPUs on monitored H3C devices, in accordance with the methodology provided in the H3C article, "Configuration Examples for Displayi ...
  10. questionHow do I install East Asian language files?
    Installations of SolarWinds NPM 10.3 and higher and newer SolarWinds installations using Orion Platform 2012.1 and higher support East Asian locales. Microsoft's East Asian Language Pack is required to view locale-specific information in SolarWinds installations on operating systems using East ...
  11. questionWhat kind of SQL Server licensing does SolarWinds require?
    Disclaimer: The following is our interpretation of Microsoft's licensing guidance. Be aware that licensing terms may change and differ between versions. If you have any doubt about your Microsoft® SQL Server® licensing terms, contact Microsoft. You do not need to worry about Microsoft S ...
  12. questionGrouping criteria are not available when creating dependencies
    Issue: Grouping criteria are not available when creating dependencies on servers using unsupported operating system locales. Description As of the release of SolarWinds Orion Platform version 2012.1, released with Orion NPM version 10.3, the following browser locales are supported: English Germ ...
  13. questionIs there an API available for the Orion family of products?
    The Orion SDK, an API available for the Orion family, is now available in the Orion SDK forum on thwack.com. For more information about downloading and beginning to use the Orion SDK, see the post, "Orion SDK Information" in the Orion SDK forum on thwack.com. This article applies to all SolarWin ...
  14. questionLocal character set is not displaying in a localized SolarWinds Orion installation
    Issue: Locale-specific characters are not displaying in a localized installation of SolarWinds Orion. Resolution: If you are using Google Chrome to view your web console, you may need to configure the browser display language, as indicated in the following steps: Click Customize and control Goo ...
  15. questionI am seeing a warning about the size of my Syslog table
    stub article for "your Syslog is too big" event FB125634
  16. questionNTA 3.9 (1): Configuration Wizard Error During Upgrade
    SolarWinds NetFlow Traffic Analyzer version 3.9 Hotfix 1 Hotfix 1 corrects an error with the Configuration Wizard during ugrade to NTA 3.9 resulting from a script that compares date-stamp differences in between current and older CBQoS data. If you are upgrading to NTA version 3.9, and you alread ...
  17. questionSolarWinds Orion products do not currently support Microsoft SQL Server 2012
    Issue: SolarWinds Orion products do not currently support Microsoft SQL Server 2012 Description: A number of features found in currently supported versions of Microsoft SQL Server are no longer included in Microsoft SQL Server 2012. As a result, SolarWinds neither recommends nor supports the use ...
  18. questionInstallation Error: "Error 1316. A network error occurred while attempting to read from the file ..\SSCERuntime-ENU.msi".
    Issue: Installation Error: "Error 1316. A network error occurred while attempting to read from the file Path\SSCERuntime-ENU.msi". This error may occur when installing a SolarWinds Orion product if any of the following versions of SQL Server are already installed on your SolarWinds server: Note: ...
  19. questionHotFix Fixes NTA 3.9 Configuration Wizard Error
    Issue: If you are running NTA 3.7 or 3.8, and you collect CBQoS data in the past but do not currently collect it, there is a possibility that you will encounter this error during the upgrade to NTA version 3.9. Error while executing script - The datediff function resulted in an overflow. ...
  20. questionAlerts are not firing after upgrade to NPM 10.2.X
    Issue: Advanced Alerts are not firing after upgrading to NPM version 10.2.X Resolution: If alerts are not firing as intended, confirm the following: The configured period of operation for the alert is correct. In some cases, the default time period may be configured as 12:00 AM to 12:00 AM, whi ...
(Page 1 of 10)      Prev | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | Next